Super Fast Charging Line Interactive Series
PROLiNK PRO701SFC is a single-phase input/ single-phase output Line-Interactive UPS system with PROLiNK’s latest Super-Fast Charging technology.
SUPER FAST CHARGING
Battery can be recharged to 90% of its capacity within 2-4 hours.
SURGE PROTECTION – PROVIDES SURGE PROTECTION FOR YOUR EQUIPMENT
Provides protection for the connected equipment from incoming spikes, surges, etc. Extra assurance while keeping your network safe from disruptive power surges.
ADVANCE EARLY WARNING OF UPS SHUTDOWN – AMPLE TIME TO BACKUP YOUR FILES
Immediately alerts you to an output overload, high temperature or low battery condition. Ample time to either correct the condition or shutdown your system before battery time runs out.
OVERLOAD PROTECTION
Initiate the alarm to inform the user in an event of an overload. Automatic shutdown, thus prolonging the lifespan of the UPS.
OVER TEMPERATURE PROTECTION
Shuts the power supply down in the event of unacceptably high internal temperatures.
INTELLIGENT BATTERY MANAGEMENT – BETTER RELIABILITY AND PROTECTION
Additional protection for battery overcharging and deep discharging. Maximizes battery performance, life and reliability through intelligent precision charging.
GENERAL
Capacity | 650VA |
Dimension (mm) | 286 x 96 x 138 (D x W x H) |
Weight (kg) | 4.3 |
INPUT
Voltage Range | 162 ~ 290VAC (Single boost)140 ~ 300VAC (Double boost) |
Frequency | 50Hz/60Hz (Auto-sensing) |
Phase | Single + GND |
OUTPUT
Voltage Range | 220-240VAC |
Battery Mode | 220-240VAC |
Frequency | 50Hz ±1% (Battery mode) |
Waveform | Simulated sine wave (Battery mode)Sine wave (AC mode) |
Transfer Time | 2ms typical |
BATTERY
Type | 12V/8.2AH x 1 |
Backup Time | 8 – 20 mins depending on load |
Recharge Time | 2-4 hours recover to 90% capacity |
INTERFACE & INDICATORS
Interface | RS232, USB port, RJ45/RJ11 (Optional) |
Display | LED/LCD Optional |
Alarm | Batt. Mode, low battery, overload, fault, etc. |
PROTECTION/MONITORING
Short Circuit Protection | Yes (Line mode & battery mode) |
Surge Protection | Yes |
Alarm | Audible & Visual |
Overload Protection | Line mode : 100 – 120% 1 min change to fault mode >120% change to fault mode immediatelyBattery mode : 100 – 120% 1 min change to fault mode >120% change to fault mode immediately |
Intelligent Battery | Prevent overcharging of battery |
Management | Protect battery and prolong battery life |
Real Panel
1. AC Mode Indicator
Green LED Lighting 2. Battery Mode Indicator Battery Normal : Yellow LED Lighting and Blinking every 30s 3. Overload and Fault Indicator Overload: Red LED Blinking every 2s 4. Power Switch 5. Power AC Input 6. Backup Outlets |
Reviews
There are no reviews yet.